Analyzer for Sound and Vibration
Smart FFT- and Octave Analyzer with 2, 4, 8 and 16 measuring channels
Overview
The low-cost sound and vibration analyzer Apollo_light hardware provides 2-16 measuring channels and additional trigger/tacho channels on the footprint of a USB hard drive. The measurement electronics is packaged in a robust, high-quality aluminium case. Ultra-low power consumption allows operation with a tablet PC. The Apollo_light is our cheapest FFT- and octave analyzer in our product range. Multiple Apollo_light devices can be synchronised for sample-synchronous operation and allow an individually adjustable sample rate for each channel.
The Apollo_light is especially well-suited for applications in:
- Occupational safety and environmental protection
- Engineering services
- Quality assurance
- Research and development
Version | Order no. | Main inputs |
---|---|---|
Apollo_lt_2B | 908046.2 | 2 x BNC |
Apollo_lt_2L | 908045.4 | 2x Lemo 7 |
Apollo_lt_4L | 908047.0 | 4x Lemo 7 |
Apollo_lt_4B | 908048.7 | 4x BNC |
Apollo_lt_8C | 908049.5 | 8x LEMO NIM-CAMAC |
Apollo_lt_8D | 908052.6 | 1x DSUB25 |
Apollo_lt_16 | 908050.1 | MDR 36, Splitter Box MDR/18x BNC |
The measurements you may implement with our modular software packages include:
- Sound level measurements
- Frequency analysis
- Signal recording
- Human vibration measurements
- Measurements of ground-propagated vibration
- Building and room acoustics
- Machinery vibration measurements
- Modal analysis
- Order analysis
- Structural analysis
Core features
Flexible operation at any PC in your company via USB interface
Highest quality at fair prices
High-precision synchronisation via cable
Highest precision provided by a 24-bit ADC in combination with a new powerful Apollo filter processor
20V and 63V microphone polarization voltage for measuring range extension of standard condenser microphones
One single measuring instrument for a wide variety of applications
Our extensive software range makes the Apollo-Box a universal measuring instrument for nearly all application fields in sound and vibration measurement.
The basic scope of the SAMURAI standard software already includes the virtual measuring instruments for time signal, sound level meter, 1/3 or 1/1 octave and FFT analyzer and reverberation time analysis. All values are calculated in real time and for each channel. SAMURAI allows data acquisition and real-time analysis as well as the post-processing of measured values without the need for data format modification due to the use of different software applications.
Software and drivers naturally downward compatible
Standards
IEC 61672: Class 1 sound level meter
IEC 60651: Class 1 sound level meter
IEC 60804: Class 1 sound level meter
IEC 61260: Class 0 filter
DIN EN ISO 8041, ISO-2631, DIN EN ISO 5349, ISO-8662, UNI-2614, UNI-11048 and UNI-9916:
HVMA weighting filters
DIN ISO 7919, ISO 2954, ISO 10816:
Evaluation of mechanical vibration
Software
SAMURAI
SAMURAI is our universal software package for the real-time noise and vibration analysis and offers comprehensive evaluation functions for post-processing. SAMURAI includes IEC 61672-1 standard sound level meters and 1/3 octaves according to IEC 61260.
SMT
The SINUS Measurement Toolbox for MATLAB® (SMT) provides the functionality of the globally established engineering tool MATLAB®.
NWWin
With Spectra's Noise & Vibration Works software for Windows we provide a feature-rich, high-performance engineering tool for the post-process evaluation of sound and vibration measurement data.
µ-Remus
Specifically designed for mechanical engineers this signal analysis software package particularly excels in modal analysis and rotor balancing.
ME'scope VES
Vibrant Technology, Inc's ME'scope VES software package offers extensive analysis capabilities for modal analyses. ME'scope allows the import of measurement data which were previously exported from our SAMURAI Transfer FRF option.
Technical specifications
PC
Processor for up to 4 measuring channels | Intel™ Atom 1,6GHz or Intel™ dual core 1,6 GHz |
Processor for more than 4 measuring channels | Intel™ dual core 2 GHz |
Storage medium | HDD oder SSD |
Interface | USB 2.0 oder USB 3.0 |
Operating system | Windows 7 oder Windows 10 |
Specifications
Apollo_lt_2B | Apollo_lt_2L | Apollo_lt_4B | Apollo_lt_4L | Apollo_lt_8C | Apollo_lt_16 | |
Input channels 2/4/8 | ||||||
Number of measuring channels | 2 | 2 | 4 | 4 | 8 | 16 |
Female input connectors | BNC | LEMO7 | BNC | LEMO7 | LEMO-NIM-CAMAC | MDR/18xBNC |
Resolution | 24-Bit | 24-Bit | 24-Bit | 24-Bit | 24-Bit | 24-Bit |
Real-time bandwidth | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz |
Dynamic range | 110 dB | 110 dB | 110 dB | 110 dB | 110 dB | 110 dB |
Noise | < 3 µV(A) | < 3 µV(A) | < 3 µV(A) | < 3 µV(A) | < 3 µV(A) | < 3 µV(A) |
Sample rates | 200 Hz bis 51,2 kHz | 200 Hz bis 51,2 kHz | 200 Hz bis 51,2 kHz | 200 Hz bis 51,2 kHz | 200 Hz bis 51,2 kHz | 200 Hz bis 51,2 kHz |
Decimation | up to 200Hz sample rate selectable per channel |
up to 200Hz sample rate selectable per channel |
up to 200Hz sample rate selectable per channel |
up to 200Hz sample rate selectable per channel |
up to 200Hz sample rate selectable per channel |
up to 200Hz sample rate selectable per channel |
Max. input voltage | ± 1 V // ± 10 V peak | ± 1 V // ± 10 V peak | ± 1 V // ± 10 V peak | ± 1 V // ± 10 V peak | ± 1 V // ± 10 V peak | ± 1 V // ± 10 V peak |
Gain | 0 dB, 20 dB | 0 dB, 20 dB | 0 dB, 20 dB | 0 dB, 20 dB | 0 dB, 20 dB | 0 dB, 20 dB |
Over-voltage detection | yes | yes | yes | yes | yes | yes |
Phase shift | < 0.1° @ 20 Hz ... 20 kHz | < 0.1° @ 20 Hz ... 20 kHz | < 0.1° @ 20 Hz ... 20 kHz | < 0.1° @ 20 Hz ... 20 kHz | < 0.1° @ 20 Hz ... 20 kHz | < 0.1° @ 20 Hz ... 20 kHz |
Offset correction | yes, automatically at auto-calibration |
yes, automatically at auto-calibration |
yes, automatically at auto-calibration |
yes, automatically at auto-calibration |
yes, automatically at auto-calibration |
yes, automatically at auto-calibration |
Input coupling | DC, AC 0,15 Hz, HP 10 Hz, LP 2 kHz |
DC, AC 0,15 Hz, HP 10 Hz, LP 2 kHz |
DC, AC 0,15 Hz, HP 10 Hz, LP 2 kHz |
DC, AC 0,15 Hz, HP 10 Hz, LP 2 kHz |
DC, AC 0,15 Hz, HP 10 Hz, LP 2 kHz |
DC, AC 0,15 Hz, HP 10 Hz, LP 2 kHz |
Microphone voltage supply | - | ± 14 V, + 20 / 63 / 200 V switchable |
- | ± 14 V, + 20 / 63 / 200 V switchable |
- | - |
IPC current supply | 2/4 mA | 2/4 mA | 2/4 mA | 2/4 mA | 2/4 mA | 2 mA |
TEDS (IEEE 1451.4) | yes | yes | yes | yes | yes | yes |
Apollo_lt_2B | Apollo_lt_2L | Apollo_lt_4B | Apollo_lt_4L | Apollo_lt_8C | Apollo_lt_16 | |
Output channels 1-2 | ||||||
Resolution | 24-bit | 24-bit | 24-bit | 24-bit | 24-bit | 24-bit |
Real-time bandwidth | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz | DC ... 20 kHz |
Max. output voltage | ± 3,16 Vpeak | ± 3,16 Vpeak | ± 3,16 Vpeak | ± 3,16 Vpeak | ± 3,16 Vpeak | ± 3,16 Vpeak |
Connector | 3.5 jack | 3.5 jack | 3.5 jack | 3.5 jack | 3.5 jack | 3.5 jack |
Trigger channels | ||||||
Trigger | 2x In: Trigger / tacho trigger level adjustable 0.1Hz ... 6MHz 2x Out |
2x In: Trigger / tacho trigger level adjustable 0.1Hz ... 6MHz 2x Out |
2x In: Trigger / tacho trigger level adjustable 0.1Hz ... 6MHz 2x Out |
2x In: Trigger / tacho trigger level adjustable 0.1Hz ... 6MHz 2x Out |
2x In: Trigger / tacho trigger level adjustable 0.1Hz ... 6MHz 2x Out |
2x In: Trigger / tacho trigger level adjustable 0.1Hz ... 6MHz 2x Out |
Dimensions and weights | ||||||
Dimensions | 180 x 105 x 22 mm | 180 x 105 x 22 mm | 180 x 105 x 22 mm | 180 x 105 x 22 mm | 180 x 105 x 22 mm | 180 x 105 x 22 mm |
Weight | 700 g | 700 g | 700 g | 700 g | 700 g | 700 g |
USB-Power consumption | 350 mA | 350 mA | 400 mA | 400 mA | 500 mA | 700 mA |
Environmental conditions | ||||||
Operating temperature range | -10 °C ... +50 °C | -10 °C ... +50 °C | -10 °C ... +50 °C | -10 °C ... +50 °C | -10 °C ... +50 °C | -10 °C ... +50 °C |
Order no. | Description |
---|---|
908185.7 | Apollo_TACHO CABLE |
908186.5 | Apollo_TRIGGER SPLITTER BOX |
971010.4 | LEMO7 / BNC ADAPTER |